T80 TurboChargerTM SPECIFICATIONS
|
| Maximum output current |
80 Amps continuous up to 45°C (113°F) ambient temperature |
| Battery voltages |
12, 24, 36 or 48 Vdc nominal |
| Max PV input current |
70 Amps |
| Input voltage range |
16 to 112 Vdc operating. 140Vdc Maximum Open Circuit Voltage |
| Max PV array power |
5200 Watts (Maximum when equalizing a 48v battery to 64v at 80 Amps) |
| Charge regulation modes |
Bulk, Absorption, Float, Standby, Auto and Manual Equalize |
| MPPT Features |
Apollo Solar patent pending MPPT algorithm harvests the optimum power under all conditions of clouds or temperature. |
| Battery temperature compensation |
6.0mV per oC per 2 volt cell |
| DC to DC conversion capability |
Charge 48v batteries from 4, 5 or 6* PV modules (nominal 17 Vmp) in series. Charge 36v batteries from 3, 4, 5, or 6* modules in series. Charge 24v batteries from 2, 3, 4, 5 or 6* modules in series. Charge 12v batteries from 1, 2, 3, 4, 5, or 6* modules in series. *Check max Voc from PV modules at low temperatures.
|
| Display |
Built-in 4 line 20 character LCD with back light |
| Status reporting |
LCD Status screen displays Input voltage & current, Output voltage & current, Charge Mode and Battery State of Charge. |
| Data logging |
Logs energy harvested for 90 days. LCD display Watt-hours, kW-hours, Amp hours and hours each day that Float mode was active. |
| Energy Monitor |
LCD shows SOC (State of Charge) in a fuel gauge style bar graph as well as % Full, Amp-hours, Watt-hrs and present charge or discharge current. A 50mV/500Amp shunt is required to use the Energy Monitor features. |
| Auxiliary relays |
Two independent relays with form A (SPST) contacts are available for control of external devices. Configurable as No or NC. Contact rating ½ Amp, 50 VDC. |
| Operating temperature and de-rating |
Full power output to +45°C ambient. Output current automatically ramped down above 45°C and softly restored as temperature decreases. |
| Standby Power |
Less than 2 Watts |
| Data Communication Options |
Card slot for optional Apollo Network and Wireless link to Remote Display. |
| Connectors |
Power lugs accept 14 to 1/0. No. 2 wire recommended. |
| Conduit knockouts |
One 1” or 1-¼” and one ½” or ¾” on left side. Two ½” or ¾” on back. Two 1” or 1-¼” on bottom. Bottom holes line up with power connectors.
|
| Unit dimensions |
38.7cm X 21.6cm X 11.1cm (15.2“ X 8.5“ X 4.4“) Length X Width X Depth |
| Shipping dimensions |
53cm X 31.8cm X 21.6cm (21“ X 12 ½“ X 8 ½“) |
| Weight |
Unit: 7.3 kg (16 lbs) Shipping weight: 10 kg (22 lbs) |
| Certification |
UL1741 |
| Environmental rating |
Indoor Type 1 (Not intended for use in extremely damp locations) |
| Included Accessory Kit |
Apollo Shunt Board and cable, battery monitor cable, and Battery Temperature Sensor (as shown in photo)
|